LEAP Bridge Steel Help

Shear Connector Locations Dialog

Opens when is Shear Connector Locations selected in the Superstructure group.
SettingDescription
Member Group Select the member group that the members are being defined for, from the drop-down list in the upper left corner of the dialog.
Members This list will show the members that encompass the selected group. Member 01 is initially highlighted by default. Click on any member to make it active for member definition activities.
Shear Connector type Select the shear connector type from the drop down list:
  • Stud - select to locate previously defined shear studs.
  • Channel - select to locate previously defined channel connectors.
  • Generic - select to define regions of composite behavior (does not need a previously stored connector).
Location Type Select the location type:
  • Relative will locate the shear connector range at a percentage of the member length.
  • Absolute will locate the shear connector range at a specified distance in feet from the beginning of the member.
Begin Location
  • If the location type is Relative, enter the location at a relative location, or percent of span length.
  • If the location type is Absolute, enter the location at the specified distance, in feet, from the beginning of the member.
End Location
  • If the location type is Relative, enter the location at a relative location, or percent of span length.
  • If the location type is Absolute, enter the location at the specified distance, in feet, from the beginning of the member.
Longitudinal Spacing Enter the longitudinal spacing between shear connector in feet.
Shear Stud Select the previously defined shear stud from the drop down list (appears for shear studs only).
Number of studs per row Enter the number of shear studs per row. (appears for shear studs only).
Transverse spacing Enter the transverse spacing between shear studs on each row in inches (appears for shear studs only).
Shear Channel Select the previously defined shear channel from the drop down list (appears for shear channels only).
Type Select Composite to define the range as fully composite or non-composite to define the range as non-composite (Generic connector type only).
Copy locations to… Select to copy shear connectors from the current member to any other member or all members.
Save DGN The following button will save the Shear Connector location 2D model directly to MicroStation DGN file format, including layers. Save the DGN file in the desired location and once the save is successful you can browse to file location and open/view in MicroStation.
OK Press this button to save all changes and exit the dialog.
Cancel Press this button to exit the dialog without saving changes.